产品详情
F<\/span> <\/span>制冷控制<\/span>:温度显示、温度控制、压缩机开机<\/span>延时<\/span>保护、温控探头故障告警、温控探头故障时可以按设定的开停比定期运行。<\/span><\/span> <\/p> F<\/span> <\/span>化霜控制<\/span>:定时<\/span>启动化霜、化霜结束条件为温度和时间双重控制、化霜滴水、<\/span>手动化霜、化霜探头故障告警。<\/span><\/span> <\/p> F<\/span> <\/span>外部告警<\/span>:有一路外部告警,可设置成常开、常**定、常闭、常闭锁定、或禁用。<\/span><\/span> <\/p> 主要技术指标:<\/span><\/span> <\/p> O<\/span> <\/span>温度显示范围: -50~125<\/span>°<\/span>C(<\/span>显示单位在-9.9~99.9<\/span>°<\/span>C之间为 0<\/span>.1<\/span>°<\/span>C,其它温度范围为<\/span>1<\/span>°<\/span>C)<\/span> <\/span><\/span> <\/p> O<\/span> <\/span>温度设定范围: -45~120<\/span>°<\/span>C(<\/span>设置步长在-9.9~99.9<\/span>°<\/span>C之间为 0<\/span>.1<\/span>°<\/span>C,其它温度范围为<\/span>1<\/span>°<\/span>C)<\/span><\/span> <\/p> O<\/span> <\/span>电源电压 <\/span>: AC 220V<\/span>±10%<\/span><\/span>或380V<\/span>±10%<\/span><\/span> 50Hz (参见产品后贴)<\/span><\/span> <\/p> O<\/span> <\/span>使用环境 <\/span>: <\/span>温度-10<\/span>℃~<\/span>45<\/span>℃,湿度<\/span><\/span>≤<\/span>85%,无凝露。<\/span><\/span><\/span> <\/p> O<\/span> 输出触点容量:<\/span> 2A/380VAC<\/span>(纯阻性负载)<\/span><\/span> <\/p> O<\/span> 温度传感器 <\/span>: NTC R25=5kΩ,B(25/50)=3470K <\/span> <\/span><\/span><\/span><\/span><\/span><\/span> <\/p> O<\/span> 执行标准 <\/span>: <\/span>Q/320585 XYK 01-200<\/span>4 (NA320-CTDA<\/span> <\/p> <\/li><\/div>